Manufacturer
FOWLER
Package
-
Packaging
Detection scope
0-100%LEL
0-10000umol/mol (ppm)
0-1000ppm,0-0.1%V0L,0-0.8%LEL,0-1250mg/M³
0-100ppm,0-0.01%V0L,0-152mg/M3,0-0.23LEL%
0-100umol/mol
0-30%VOL
0~1000μmol/mol
0~100PPM
-
Protection level
IP65
-
transmission distance
-
Working current
200mA
-
working voltage
3.6V
4.5V
DC 3.7V
DC3.7V (Lithium Battery Capacity 2000mAh)
-
type
Ammonia Gas Detector
Carbon Monoxide Detector Alarm
Combustible Gas Detection Alarm
Hydrogen Sulfide Detection Alarm
Hydrogen Sulfide Detector
Oxygen Detection Alarm
Gaobao
About 2000PPM
-
response time
2 Seconds
Approximately 10 seconds
Instantaneous
Less than 30 seconds
T<30s
≤120 seconds
-
Appearance dimensions
130*65*45mm
200*70*25mm
229*114*137mm
55.7*29.9*135.5mm
67.98*28.47*119.98mm
68.85*29*132.98mm
71*153*49mm
-
Environmental pressure
-
Power supply voltage
-
resolving power
1ppm
1umol/mol(ppm)
Carbon Monoxide: 1
Flammable gas: 0.1
Hydrogen Sulfide: 0.1
Oxygen: 0.1
-
weight
104g (excluding battery)
2.7kg (including batteries)
218.7g (including batteries)
-
Alarm point
Configurable, Default Low Alarm: 500 µmol/mol, Default High Alarm: 2000 µmol/mol
-
Slipping height
-
Detection method
-
Power supply
3*1.5V AAA Alkaline Batteries
-
Working hours
-
Automatic shutdown
About 5 Minutes (No Operation)
-
work environment
0-50℃
0~50℃
0°C~50°C
Temperature -20°C~50°C, humidity <95%RH without condensation
Temperature -20℃-50℃, humidity <95%RH without condensation
~20-50℃
~30-50℃
-
accuracy
-
Over range alarm
-
Indication method
LCD Displays Real-time Data and System Status, LED, Sound, Vibration Indication Alarm, Low Battery Display Prompt
LCD displays real-time data and system status, LED, sound, and vibration indicate alarms, faults, and undervoltage
-
Speed time
-
Detector length
-
Display error
≤±5%FS
-
Shell material
Waterproof type
-
Underreporting
Approximately 500PPM
-
stability
-
range
-
Environmental humidity
0-95% RH non-condensing
15-90%RH
<95%RH, no detergent
-
Detecting gas types
Ammonia (NH3) concentration in air
Carbon Monoxide (CO)
Combustible Gas
Combustible gas, oxygen, carbon monoxide, hydrogen
Hydrogen Sulfide H2S
Oxygen
-
category
-
Alarm value setting
-
Probe length
-
power
-
function
Commonly Used for Combustible Gas Network, Oxygen, Carbon Monoxide, Hydrogen Sulfide
-
Repeatability
-
Charging interface
-
Preheating time
-
Internal dimensions
-
Sound level intensity
-
Remarks
Model + Type
-
Reset All
Results: 13
Showing
1 - 13
Of 13
|
|
Mpn |
Manufacturer |
Quantity |
Description |
Package |
Packaging |
Date Code |
Detection scope |
Protection level |
transmission distance |
Working current |
working voltage |
type |
Gaobao |
response time |
Appearance dimensions |
Environmental pressure |
Power supply voltage |
resolving power |
weight |
Alarm point |
Slipping height |
Detection method |
Power supply |
Working hours |
Automatic shutdown |
work environment |
accuracy |
Over range alarm |
Indication method |
Speed time |
Detector length |
Display error |
Shell material |
Underreporting |
stability |
range |
Environmental humidity |
Detecting gas types |
category |
Alarm value setting |
Probe length |
power |
function |
Repeatability |
Charging interface |
Preheating time |
Internal dimensions |
Sound level intensity |
Remarks |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
- | 4.5V | 2 Seconds | 68.85*29*132.98mm | - | 3*1.5V AAA Alkaline Batteries | - | 0~50℃ | - | - | 30 cm | - | - | - | ||||||||||||||||||||||||||||||||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
- | IP65 | DC3.7V (Lithium Battery Capacity 2000mAh) | - | 130*65*45mm | - | - | Temperature -20°C~50°C, humidity <95%RH without condensation | LCD displays real-time data and system status, LED, sound, and vibration indicate alarms, faults, and undervoltage | ≤±5%FS | Combustible gas, oxygen, carbon monoxide, hydrogen | - | ||||||||||||||||||||||||||||||||||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0-10000umol/mol (ppm) | IP65 | DC 3.7V (Lithium battery capacity 2000mAh) | T<30s | 200*70*25mm | 1umol/mol(ppm) | Configurable, Default Low Alarm: 500 µmol/mol, Default High Alarm: 2000 µmol/mol | - | - | Temperature -20℃-50℃, humidity <95%RH without condensation | - | LCD Displays Real-time Data and System Status, LED, Sound, Vibration Indication Alarm, Low Battery Display Prompt | - | Combustible Gas | - | |||||||||||||||||||||||||||||||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
- | - | About 2000PPM | Instantaneous | - | - | - | About 5 Minutes (No Operation) | - | - | - | Approximately 500PPM | - | Commonly Used for Combustible Gas Network, Oxygen, Carbon Monoxide, Hydrogen Sulfide | ||||||||||||||||||||||||||||||||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
- | - | - | - | - | - | - | 229*114*137mm | - | - | - | 2.7kg (including batteries) | - | - | - | - | - | - | 0°C~50°C | - | - | - | - | - | - | Waterproof type | - | - | - | 0-95% RH non-condensing | - | - | - | - | - | - | - | - | - | - | - | - | ||||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0-100%LEL | - | - | - | DC 3.7V | Combustible Gas Detection Alarm | - | Less than 30 seconds | 71*153*49mm | - | - | Flammable gas: 0.1 | 218.7g (including batteries) | - | - | - | - | - | - | ~20-50℃ | - | - | - | - | - | - | - | - | - | - | <95%RH, no detergent | Combustible Gas | - | - | - | - | - | - | - | - | - | - | Model + Type | |||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0-30%VOL | - | - | - | DC 3.7V | Oxygen Detection Alarm | - | Less than 30 seconds | 71*153*49mm | - | - | Oxygen: 0.1 | 218.7g (including batteries) | - | - | - | - | - | - | ~20-50℃ | - | - | - | - | - | - | - | - | - | - | <95%RH, no detergent | Oxygen | - | - | - | - | - | - | - | - | - | - | Model + Type | |||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0~1000μmol/mol | - | - | - | DC 3.7V | Carbon Monoxide Detector Alarm | - | - | 71*153*49mm | - | - | Carbon Monoxide: 1 | 218.7g (including batteries) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Carbon Monoxide (CO) | - | - | - | - | - | - | - | - | - | - | Model + Type | |||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0-100umol/mol | - | - | - | DC 3.7V | Hydrogen Sulfide Detection Alarm | - | Less than 30 seconds | 71*153*49mm | - | - | Hydrogen Sulfide: 0.1 | 218.7g (including batteries) | - | - | - | - | - | - | ~20-50℃ | - | - | - | - | - | - | - | - | - | - | <95%RH, no detergent | Hydrogen Sulfide H2S | - | - | - | - | - | - | - | - | - | - | Model + Type | |||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0-1000ppm,0-0.1%V0L,0-0.8%LEL,0-1250mg/M³ | - | - | - | - | Carbon Monoxide Detector Alarm | - | Less than 30 seconds | 67.98*28.47*119.98mm | - | - | - | - | - | - | - | - | - | - | ~30-50℃ | - | - | - | - | - | - | - | - | - | - | 15-90%RH | - | - | - | - | - | - | - | - | - | - | - | Model + Type | |||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0-100%LEL | - | - | 200mA | 3.6V | Combustible Gas Detection Alarm | - | Approximately 10 seconds | 67.98*28.47*119.98mm | - | - | - | - | - | - | - | - | - | - | 0-50℃ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Model + Type | |||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0-100ppm,0-0.01%V0L,0-152mg/M3,0-0.23LEL% | - | - | - | - | Hydrogen Sulfide Detector | - | Less than 30 seconds | 67.98*28.47*119.98mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Model + Type | |||
|
|
Full Reel: |
Gas Detectors RoHS |
- |
- |
0~100PPM | - | - | - | - | Ammonia Gas Detector | - | ≤120 seconds | 55.7*29.9*135.5mm | - | - | 1ppm | 104g (excluding battery) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Ammonia (NH3) concentration in air | - | - | - | - | - | - | - | - | - | - | Model + Type |